www.CalcoloStrutture.com

info@calcolostrutture.com

        


17/03/2010
ATTENTION! How to improve your productivity


In this period we talk always about crisis, about economy and its difficult to resume, about stactionary building trade.
While you read this news you have in your mind your professional situation, your loan to pay, your collaborators to satisfact, your housewife, your son...ever more problem, ever more negative tought.
After you have been ill-treat by competition you've done.
You have signed a new contract.



20/01/2010
Chiarimenti per l'applicazione del DM 14.01.2008


Molte sono le incertezze circa l'applicabilità del nuovo decreto ministeriale sulle costruzioni, soprattutto quando si parla di variante in corso d'opera. L'articolo, vuole finalmente definire un punto fermo ...


18/12/2009
Executive design of lamellar wood structures in seismic area


New extraordinary publication by Eng. Albano Giuseppe

Prescriptions - Predimensionment's methods - constructing details - executives design of buildingsite with Cd-Rom for Window 98 operating system or successives containing: Constructing details in DWG form - Example of buildingsite's executive project - Support tools for the calculations.
19/11/2009
HAPPY EASTER TO EVERYONE WHO CAN...

The tragedy that striked the Abruzzo's area left inside my professionality, inside my capacities, if they could ever be
so, something really empty...
the observation that I would make with you, a technician like me, it's this one:


Strctural plan in reinforced concrete for a residence building












The examinated building in the calculating report develops for 1 floor above to the ground through than the covering and the basement; the planimetric distribution foresee, for each floor, two estate unities reachable through a stairwell with relatives concrete slab flights.




The structural type of the building we're showin' you about could be called a mixed type, divisors in reinforced concrete and frames in reinforced concrete. In fact, at the basement it's possible to see, by the graphics elaboratings attached to the this report, that have been arranged walls of 16 cm having the double function to compartiment rooms by the fire(at least REI 60) and portant function. These divisors have been arranged  and araised  untill the covering floor just to guarantee the best uniforming masse's redistributon for all floors. The building has been calculated making reference to the 2008's MD (Technical rules for constructions) paying attention to the resistances' hierarchy's criteria and to the geometrical limitations and also about frameworks setted up by the ministerial decree.




     
 

  Home page   |   Chi siamo   |   Calcoli on-line   |   Normativa   |   Progettazione Strutturale   |   Lavori   |   Link utili   |   Contattaci   |

www.calcolostrutture.com - P.I.02329810713